Спасибо!

Мы исправим ошибку в ближайшее время

Сообщить об ошибке

Site Tools


Displaying an additional parameter

Displaying an additional parameter and returning to the default information is enabled by long-pushing (i.e. longer than 3 s) the button.

If necessary, you can set up one of the additional parameters:

1. Displaying the volume of fuel added during the refuelling operation.

This parameter allows you to monitor both the total volume of fuel added to the tank, and the volume of fuel in each tank.

In Omnicomm Configurator, in the “Settings” section, in the “Additional parameter» field, select the “Volume of fuel added during the refueling operation” option.

Before starting the refuelling operation, please, switch to the mode of displaying the additional parameter by long-pushing the button. Start the refuelling operation. The Omnicomm LLD-HD indicator will display the volume of fuel being added to the tank.

Short-pushing the button will allow you to go to the next value viewed on the display:

  • total volume of fuel added (the Σ LED blinking light);
  • volume of fuel added according to the 1st Omnicomm LLS sensor’s readings (the 1 LED blinking light);
  • volume of fuel added according to the 2nd Omnicomm LLS sensor’s readings (the 2 LED blinking light).

2. Displaying the value of vehicle speed transmitted from the Terminal.

This parameter allows you to monitor the vehicle speed.

In Omnicomm Configurator, in the “Settings” section, in the “Additional parameter” field, select the “Terminal’s data” option.

Enable the feature of displaying the speed by long-pushing the button.

3. Displaying the value read from the Terminal’s universal input.

This parameter allows you to monitor the Terminal’s universal input status or value, depending on the type of the connected auxiliary equipment.

In Omnicomm Configurator, in the “Settings” section, in the “Additional parameter” field, select the “Terminal’s data” option.

Enable the feature of displaying the parameter by long-pushing the button.

4. Displaying the volume of fuel dispensed from a fuel tanker truck.

This parameter is only available for the Omnicomm Profi 2.0 Terminal, which is provided with the connected signal pickup device (USS).

In Omnicomm Configurator, in the “Settings” section, in the “Additional parameter” field, select the “Terminal’s data” option.

Before starting the fuel dispensing operation, please switch to the mode of displaying the additional parameter by long-pushing the button. Start the fuel dispensing operation. The Omnicomm LLD-HD indicator will display the volume of fuel being dispensed through the dispensing nozzle.

Short-pushing the button resets the displayed value.

The additional parameter can be displayed by default upon switching the Omnicomm LLD-HD indicator on. For this purpose, in Omnicomm Configurator, in the “Settings” section, in “The display mode at startup” field, select the “Additional parameter” option.

To display the vehicle speed, the values read from the universal input and the volume of fuel dispensed, it is necessary to edit the appropriate settings of the Omnicomm Terminal.