Connect the Omnicomm LLD-HD indicator to the PC according to the scheme:

Scheme of connecting the <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLD-HD</k> to the PC

or

Scheme of connecting the <k style='word-break:keep-all;white-space:nowrap'>Omnicomm LLD-HD</k> to the PC

Launch Omnicomm Configurator:

The “Settings” window of the Omnicomm Configurator

In the menu, click “Tools” / “Settings” / “Connection” and specify the connection port and speed for the Omnicomm LLD-HD indicator when connected via the UNU-USB (or UNU) adjusting tool.

In the “Settings” section:

  1. Specify the rate for data exchange via the EIA-485 interface. For firmware update, set the data exchange rate to the value of 19200 bit/sec.
  2. Specify the number of sensors connected to the Omnicomm LLD-HD indicator.
  3. Specify the network addresses that are set in the Omnicomm LLS-HD fuel level sensors.
  4. Set the brightness level for the indicator at startup. The following options are available: maximum, minimum, off. The minimum brightness level is set by default.
  5. If necessary, set one of the additional parameters (Displaying an additional parameter).
  6. Click on the “Save in the indicator” button.

In the “Calibration” section, fill out the calibration table for each Omnicomm LLS-HD fuel level sensor, or download it from the previously saved file by clicking “Import” and selecting the “From the calibration file (.ctb)” option:

The “Settings” window of the Omnicomm Configurator

Click on the “Export” button and select the “Into the indicator” option. To save the calibration table, click “Export” and select the “Into the calibration file (.ctb)” option.