Спасибо!

Мы исправим ошибку в ближайшее время

Сообщить об ошибке

Site Tools


Sealing

For Omnicomm LLS sensors, the bolt or the self-tapping screw and the connection may be sealed as shown below: Пломбирование болта Установка пломбы

1. Install the bolt or the self-tapping screw through a hole in the seal

2. Close the seal cover with a snap

3. Enter the seal and cover numbers in the report

Put the rotary seal on Omnicomm LLS 30160 connector:

Пломбирование разъема

1. Put the sealing wire through the holes in the connectors and in the rotary seal

2. Twist the seal tab to tighten the wire

3. Tear the seal tab off

Install the seal-tie on Omnicomm LLS-AF 4 connector:

Пломбирование разъема

  1. Connect Omnicomm LLS-AF 4 connector to the mounting cable until it clicks
  2. Run the flexible part of the seal through the connectors
  3. Run the flexible part of the seal through the hole in the seal body
  4. Tighten up the connection
  5. Cut off the extended section of the flexible part of the seal