Remote Correction of the Full/Empty Calibration

The Full/Empty recalibration of the Omnicomm LLS 4 fuel level sensor is required when the sensor calibration changes. It manifests as a discrepancy of readings from the sensor when the tank is empty or full (e.g., when fuel characteristics change, dirt accumulates on the measuring part during long operation, or the sensor is installed incorrectly). Recalibration is required when a horizontal section appears in the Fuel Volume report in Omnicomm Online when the tank is full and the vehicle is moving, as shown below:

Fuel volume report

If recalibration is required, it is recommended to carry out service maintenance of the Omnicomm LLS 4 fuel level sensor. As a temporary measure, before the maintenance can be carried out and if the fuel level sensors are connected to Omnicomm terminals with firmware version FW309 and above, perform recalibration using SMS commands:

Command Designation
Command text in SMS Reply to a command in SMS Example of command / reply
*GETCNTINFO# GETCNTINFO
LLS1: CNTmin1, CNTmax1, CNT_T
LLS2: ….VID = 336xxxxxxx, where
CNTmin1 , CNTmax1, CNT_current1 – “empty”, “full”, current values
VID – terminal ID
LLS1: 90000, 172202, 129893
LLS2: 50000, 350000, 132485
VID=326001571
Request current CNT readings (“empty”, “full”)
*SETCNT pwd numlls CNTmin2 СNTmax2#
where pwd – password to change terminal settings
numlls – sensor network address
CNTmin2 СNTmax2 – “empty” and “full” new values
SETCNT OK – SMS worked correctly
SETCNT PWD ERR – wrong or no password entered
SETCNT ERRVALUE – incorrect CNT values entered
SETCNT ERRPARAM – incorrect SMS format
*SETCNT pass 1 42000 300000# Set new СNT_empty/full values (CNTmin2 and СNTmax2)
*SETCNTFULL pwd numlls koef_empty#
where pwd – password to change terminal settings
numlls – sensor network address
koef_empty – “empty” value change flag
koef_empty = 0, then CNT_empty does not change
koef_empty = 1, then СNT_empty increases by the same amount as CNT_full
SETCNTFULL OK – SMS worked correctly
SETCNT PWD ERR – wrong or no password entered
SETCNTFULL ERRVALUE – Conditions outlined in the Limitations were not met
SETCNT ERRPARAM – wrong SMS format
*setcntfull pass 1 0# Automatic correction of the CNT_empty/full values

Perform automatic correction of values on one sensor and only on a full tank. Fill a full tank and send the SMS command to the terminal. Corrected values must not differ from the set ones by more than 15%.