Спасибо!

Мы исправим ошибку в ближайшее время

Сообщить об ошибке

Site Tools


Technical Specifications

Omnicomm LLS-Ex 5 sensors

Parameter Value
Level measurement range depending on the version, mm 0…700, 1000, 1500, 2000, 2500, 3000, 4000, 5000, 6000
REF-channel length, mm - for sensors of 700, 1000 mm length - 200
- for sensors of 1500 mm length - 700
- for sensors of 2000, 2500 mm length - 1000
- for sensors of 3000 mm length - 1500
- for sensors of 4000 mm length - 2000
- for sensors of 5000 mm length - 2500
- for sensors of 6000 mm length - 3000
Limit of the allowed main reduced error of level, % ± 0,5 (when working with fuel for which the calibration have been performed, or upon filling up the tanker full in case of changing fuel type)
Interface for measured values output RS-232, RS-485
Programmable interface transmission rate, bit/s 1200, 2400, 4800, 7200, 9600, 14 400, 19 200, 38 400, 57 600*, 115 200*
Measured values output protocol (protocol auto-detection) LLS, Modbus
Power supply voltage, V 5,1
Power consumption, not more than, W 0,4
Current consumption, not more than, mA 40
Body protection rating IP69k
Electric strength of galvanic insulation, not less than, V 7000
Terms of Use:
Ambient temperature, °С From -40 to +80
Extreme temperatures, °С From -60 to +85
Maximum humidity, % 100
Digital code range corresponding to the maximum level measurement value 1…4095
Digital code range corresponding to the minimum level measurement value 0…4095
Temperature measuring range, °C From -40 to +80
Measurement time period, sec 1
Automatic data output interval, sec From 1 to 255
Operating mode Continuous
Overall dimensions, cm 87.3 x 83.5 x (21 + measuring probe length)
Weight, not more than, kg 2
Average service life before sensor failure, not less than, hours 100 000
Average service life, years 12
** In addition to LLS-Ex 5 sensors when connected via RS-232 interface using 20 meter KTZ cable

BIS-MX Spark protection unit

Parameter Value
Power supply voltage, V 8 - 50
Maximum input voltage Um, V 250
Open-circuit voltage U0, V 2 x 5.1
Short-circuit current I0, A 2 x 0.13
Maximum external capacitance С0, µF 2 x 15
Maximum external inductance L0, mH 2 x 1.0
Operating temperature range, °С From -60 to +80
Body protection rating IP69k
Overall dimensions (without cables), mm 138 х 115 х 56
Weight, not more than, kg 0.9
Average service life, years 12