Спасибо!

Мы исправим ошибку в ближайшее время

Сообщить об ошибке

Site Tools


Fuel Tank Preparation

1. Select the location for Omnicomm LLS sensor installation, taking into account the following requirements:

  • The installation location should be as close to the geometric center as possible and be placed at the deepest level of the tank:

Выбор места установки датчика Omnicomm LLS

  • When installed, the sensor should not be in contact with reinforcement ribs and existing equipment inside the tank
  • Installing two sensors in one fuel tank allows to significantly reduce the influence of the vehicle inclination angle on the fuel level:

Место установки двух датчиков Omnicomm LLS

2. Steam out the tank to comply with safety regulations

3. Drill out the central bore using a bimetal hole saw ø35 mm

4. Drill out four mounting holes according to the diagram:

Подготовка места установки датчика Omnicomm LLS

The mounting hole diameter depends on the material of the tank:

  • ø 4 mm – for metal tanks with wall thickness over 3 mm (cut M5 thread)
  • ø 7 mm – for plastic and metal tanks with wall thickness up to 3 mm (for rivets)
  • ø 4 mm – for plastic tanks with wall thickness over 3 mm