RS-485 and RS-232 Interfaces

Connection of auxiliary equipment (CAN-Log, PP-01 passenger throughput sensors, DV-1 driver display, JPEG camera, data reception from vehicle J1708 data bus, reception and transmission of navigation data as per NMEA standard) is carried out through RS-485 and RS-232 interfaces. When needed, it is recommended to use the RS-232 to RS-485 converter.

In the “Settings” window open the “Inputs” tab: Omnicomm Configurator Remote configuration server

For Omnicomm Smart terminal you may only configure interface RS-485.

For RS-485 and RS-232 interfaces choose the setting:

  • “Disabled” – interface is not used
  • “CAN-log” (for RS-232 interface only) – connection to a CAN-log device (CAN-LOG P protocol V1, CAN-LOG B protocol V2, CAN-LOG B protocol V4)
  • “J1708” – connection to the vehicle J1708 data bus
  • “NMEA reception” – use of navigation data from an external device. If you select this option, you must specify the data port bit rate. “RS port bit rate for NMEA data” – select the data port bit rate for reception of navigation data from an external device
  • “NMEA transmission” – use of the terminal navigation data in an external device
  • “PP-01” – use for connection of the passenger throughput sensor
  • “Camera” – use for the digital camera connection
  • “DV-01” – use for the driver display connection
  • “LLS / LLD” – use for connecting fuel level sensors Omnicomm LLS, Omnicomm LLD indicator
  • “Tachograph VDO” (only in Omnicomm Configurator) – use for Continental tachograph connection
    • “Frequency of data transfer to the server” – select the number of days for the DDD files transmission to the communication server. Possible options: from 1 to 28 days.
    • “Remove private data before transmission” - if necessary, enable deleting the driver's personal data prior to data submission to the server.
  • “iQFreeze” – use for connection of the refrigerator control device
  • “ALM Weight Indicator” – use for connection to the axle load monitoring device
  • “Modbus (Struna +, PMP-201)” – use for connection to the level gauge PMP-201 or the Struna + system
  • “Custom Modbus” – is used to connect equipment which operates with Modbus protocol standard (except for Smart)
    • “Port baud rate” – specify the Modbus port baud rate operation Possible options: 9600, 19200, 38400, 57600, 115200.
    • “Port settings” – select the port settings Possible options: 8-N-1, 8-N-2, 8-Е-1, 8-Е-2, 8-О-1, 8-О-2.
  • “TPMS Pressure Pro” (only for RS-232 interface) – use for connection of the tire pressure sensors though TPMS Pressure Pro protocol
  • “Truck-TPMS” (only for RS-232 interface) – use for connection of the tire pressure sensors though Truck-TPMS protocol
  • “TPMS 6-13” (only for RS-232 interface) – use for connection of the tire pressure sensors though TPMS 6-13 protocol. The terminal transmits temperature data with an interval of 20 degrees: -40,-20, 0, +20,…, +100. The frequency and transmission depend on the energy-saving settings of the wireless pressure sensors configured in accordance with the TPMS user manual.

Fuel Level Sensors

In the “Settings” tab select the “Inputs” section from the list.

In the “Fuel Level Sensors” section:

Omnicomm Configurator Remote configuration server

“Data source” – select the type of fuel level sensors. Possible options:

  • “Digital LLS” – when connecting fuel level sensors Omnicomm LLS
  • “Frequency LLS-AF” – when connecting fuel level sensor Omnicomm LLS-AF
  • “Vehicle sensor” – when connecting the vehicle standard fuel sensor
  • “CAN Bus” – when connecting to the CAN bus
  • “Struna +” (except for Smart) – when connecting to the “Struna +” system
  • “PMP-201” (except for Smart) – when connecting the level gauge PMP-201
  • “Disabled” – in case fuel level control is not required.

When Omnicomm LLS and Omnicomm LLS-AF fuel level sensors are connected:

“Number of connected sensors” – specify the number of sensors connected to the terminal.

When choosing LLS fuel level sensors connected to a universal input, you need to configure the universal input. For automatic configuration of the universal input in Omnicomm Configurator press the “Configure UI” button.

“Filtration” – enter the size of inner filter. Possible options of filtration:

  • “None” – filtration is performed only according to the settings in the Omnicomm LLS sensor
  • “Weak” – used in case of product installation in stationary fuel storages and non-mobile machinery
  • “Medium” – used in case of vehicle's operation in normal road conditions
  • “Strong” – used in case of vehicle's operation in normal and severe road conditions
  • “Maximum” – used in case of vehicle's operation in severe road conditions and when connecting a standard fuel sensor with analog output

When connecting to the “Struna +” system or the “PMP-201” sensor:

  • “Fuel tank volume, L” – enter the fuel tank volume. Possible values: 0 to 65,000
  • “Current fuel volume, L” – displays the current volume according to the “Struna +” system or the “PMP-201” sensor

Connect the “PMP-201” sensor and the “Struna +” system according to the documentation on these devices. You may connect only one “Struna +” system. The network address, by default, is 80.

Connect one Omnicomm LLS fuel level sensor to the Terminal Omnicomm Profi, Profi Wi-Fi according to the diagram:

Connect Omnicomm LLS fuel level sensor

Connect Omnicomm LLS-AF fuel level sensor to the Terminal Omnicomm Profi, Profi Wi-Fi according to the diagram:

Connection of the Omnicomm fuel level sensor <k style='word-break:keep-all;white-space:nowrap'><k style='word-break:keep-all;white-space:nowrap'>LLS-AF</k> 20310</k>

Connect several Omnicomm LLS-AF sensors to the terminal one by one, starting with 1 universal input. Only one Omnicomm LLS-AF sensor can be connected to the Omnicomm Smart and Smart Promo terminals.

Omnicomm LLS-AF sensor must be set to output a frequency signal in the range from 30 to 1053 Hz.

Connect one Omnicomm LLS fuel level sensor to the terminal Omnicomm Optim and Smart according to the diagram:

Connection of the Omnicomm fuel level sensor Omnicomm LLS 30160 Connect one or more Omnicomm LLS fuel level sensors side-by-side via the RS-485 interface.

Connect Omnicomm LLS-AF fuel level sensor to the terminals Omnicomm Optim and Smart according to the diagram:

Connection of the Omnicomm fuel level sensor Omnicomm LLS 30160

When connecting the terminals to the “Struna +” system or the “PMP-201” sensor:

  • “Fuel tank volume, L” – enter the fuel tank volume. Possible values: 0 to 65,000
  • “Current fuel volume, L” – displays the current volume according to the “Struna +” system or the “PMP-201” sensor

Connect the “PMP-201” sensor and the “Struna +” system according to the documentation on these devices. You may connect only one “Struna +” system. The network address, by default, is 80.

Omnicomm LLD Indicator

In the “Settings” tab select the “Additional equipment” section from the list.

In the “Data transmission to Omnicomm LLD indicator” section

Omnicomm Configurator Remote configuration server

“Data source” – select the data source to display the value on the Omnicomm LLD indicator. Possible options:

  • “GPS speed” – displays the vehicle speed
  • “Universal input“ – displays the status or values on the terminal universal input depending on the connected auxiliary equipment
  • “Engine hours by RPM” (only for Profi, Profi Wi-Fi, Optim) – displays vehicle engine hours

When selecting “Motor hours by RPM”, fill in the table of RPM recalculation to motor hours as follows:

In the field “Revolutions per minute” enter the value of RPM, in the field “Factor” enter the value of conversion factor to calculate the motor hours value.

The conversion factors are determined based on the operating conditions of the vehicle.

Maximum number of rows – 5.

Engine hours are displayed on the LLD indicator as hour values with a fractional part (1.50 means 1 hour 30 minutes) in the format HH.XX in the range of up to 100 hours and HHH.X in the range of 100.0 to 999.9 engine hours. If the number of engine hours is more than 1000, the last three significant figures are displayed and one symbol after the decimal point.

Motor hours are fully recorded in the terminal and sent to the CS on a continuous accrual basis.

Omnicomm ICON Display

In the “Settings” tab select the “ICON” section from the list.

Настройка ICON

“ICON” – check the box to display data from the terminal on the Omnicomm ICON Display

  • “Network address” – select the display network address. Possible values: from 7 to 254
  • “Select a time zone” – check the box to select the time zone with reference to UTC. The value of the time zone is used in case where automatic accounting of time zones is not required

“Time zone” – select the time zone

  • “Notify on status change via SMS” – check the box to send SMS to the dispatcher’s number about changing the driver's status. Notification contains the new status of the driver.
  • “Sound notification” – check the box to enable sound notification when registering the event specified when configuring the terminal and the display

In the “Settings” tab select the “Additional equipment” section from the list.

“Engine hours by RPM”, fill in the RPM to engine hours conversion table:

 Engine hours by RPM

Enter the RPM value in the “RPM” field, in “Coefficient” field enter the value of conversion factor to calculate engine hours.

The conversion factors are determined based on the vehicle operating conditions. Maximum number of rows – 5.

The engine hours are displayed in hours with a decimal part (1.50 equals to 1 hour and 30 minutes) in the format HH.XX within the range of up to 100 engine hours and HHH.X for 100.0 - 999.9 engine hours. If the number of engine hours is higher than 1000, the last three significant digits and one symbol after the decimal point are displayed.

All engine hours are recorded in the terminal and sent to the CS as accrued total.

Connect Omnicomm Profi terminal to Omnicomm ICON display according to the diagram:

 Connection of several Omnicomm LLS sensors

Connect Omnicomm Profi, Smart terminal to Omnicomm ICON display according to the diagram:

 Connection of several Omnicomm LLS sensors

Tachograph

Connect the Continental tachograph to the Optim terminal via RS-232 and RS-485 according to the diagram:

Tachograph

Power connections of the terminal and the tachograph must be made similarly: either both before, or both after the vehicle battery disconnect switch.

If needed, it is recommended to use the RS-232 to RS-485 converter.

To read the DDD files from the Continental tachograph, in the program configure the RS-232 or RS-485 interface of the terminal.

CAN-LOG controllers

Omnicomm terminals (except for Smart) support the connection of CAN-LOG controllers.

Connect the CAN-LOG, series B14, B24, B34, B44, to the vehicle's CAN bus, as shown in the diagram:

Follow the instructions provided by the CAN-LOG manufacturer during connection.

Connect the CAN-LOG to the terminal via the RS-232 interface as shown in the diagram:

In Omnicomm Configurator, in the “Settings”/“Inputs” window, in the “RS-485 and RS-232 Interface Configuration” section:

2_-_eng.jpg

“RS-485” - select CAN log.

CAN-LOG parameters, displayed in Omnicomm Online and in Omnicomm Configurator

SPN Omnicomm Online Configurator CAN-LOG series B V4 CAN-LOG series B V2 CAN-LOG series P V1
70 Park. brake status Parking brake status Yes Yes Yes
91 Acceler. pedal pos., % Accelerometer pedal position (%) Yes Yes Yes
96 Fuel level Yes Yes Yes
110 Eng. coolant temp., °C Engine coolant temperature Yes Yes Yes
175 Eng. oil temp.,°C Engine oil temperature Yes
182 Daily fuel cons., l Daily fuel consumption Yes Yes
190 Engine RPM, rpm Engine RPM Yes Yes Yes
244 Daily mileage, km Daily mileage Yes Yes
245 Odometer reading, km Total mileage Yes Yes Yes
247 Engine hour meter reading, hour:min Total engine operation time Yes Yes Yes
250 Fuel consumption meter reading, l Overall fuel consumption Yes Yes Yes
527 Cruise Control status Cruise Control status Yes Yes
582 Axle load, kg Axle load Yes Yes Yes
597 Serv. br. ped. status Status of the service brake pedal Yes Yes Yes
598 Clutch ped. status Status of the clutch pedal Yes Yes
914 Mileage before maintenance, km Mileage before next maintenance Yes Yes
916 Engine hours before maintenance, h Time before next maintenance Yes Yes
1624 Inst. speed, km/h Instantaneous speed Yes Yes Yes

Custom Modbus

The Omnicomm Profi and Optim terminals with the firmware version of FW310 or higher support the connection of an external device operating via the Modbus protocol.

Only one device working via the Modbus protocol can be connected to the terminal.

Pre-check the settings of an external device: port, baud rate, and device IP-address.

Connect an external device via the RS-485 or RS-232 interface.

Connect an external device via the RS-485 interface to the Omnicomm Profi and Optim terminals according to the diagram:

External device

Connect an external device via the RS-232 interface to the Omnicomm Profi and Optim terminals according to the diagram:

External device

Follow the instructions provided by the external device manufacturer during connection.

In the Omnicomm Configurator program in the “Settings” / “Inputs” window or in the remote configuration server in the “RS-485 and RS-232 interfaces configuration” section:

Omnicomm Configurator RCS

“Custom Modbus” is used to connect equipment which operates with Modbus protocol standard (except for Light, Smart).

When selecting “Custom Modbus”:

“Port baud rate” – specify the Modbus port baud rate operation Possible options: 9600, 19200, 38400, 57600, 115200.

“Port settings” – select the port settings. Possible options: 8-N-1, 8-N-2, 8-Е-1, 8-Е-2, 8-О-1, 8-О-2.

In the Omnicomm Configurator, the terminal operation mode is configured and the parameters are added in the “Settings” / “Modbus” (see Modbus).